Ethylene Oxide (EO) Residue Testing
TestCert Lab carries out ethylene oxide (EO) residue testing for medical devices sterilized with EO gas. The test measures how much ethylene oxide and ethylene chlorohydrin (ECH) remain on a device after sterilization and aeration, so you can show that residues are within safe limits before products are released.
Why EO residue testing is required
Ethylene oxide is an effective sterilant for heat-sensitive devices, but it is toxic. Residues must fall below limits set by device category and contact duration before the product reaches a patient. Regulators and notified bodies expect EO residue data in the technical file for every EO-sterilized device, and many buyers request it with each shipment.
Standards commonly requested
- ISO 10993-7: ethylene oxide sterilization residuals
- Limits applied according to patient contact: limited, prolonged or permanent
Products we test
- Catheters, tubing and infusion sets
- Syringes and single-use plastic devices
- Surgical kits, drapes and gowns
- Wound dressings and other EO-sterilized products
Samples and turnaround
Samples should be taken at a defined time after sterilization and sealed promptly so results reflect the product as shipped. Tell us the sterilization date, aeration time and device category, and we will confirm the number of samples and expected timeline.
What your report includes
The report states the extraction method, measured EO and ECH levels, the applicable limits for your device category, and whether the product complies, ready for your technical documentation.
Related tests
Request a quote for ethylene oxide residue testing
Tell us about your product and the standard you need, and we will confirm samples, cost and timeline.
Or call +92 321 8617100 · email info@testcert.org
Ethylene Oxide (EO) Residue Testing FAQs
What limits apply to EO residues?
ISO 10993-7 sets limits based on how long the device contacts the patient. We apply the limits for your device category and state them in the report.
When should samples be taken after sterilization?
Take them at the aeration time you intend to use for release, and send them sealed as soon as possible so the result reflects the shipped product.
Do you also test sterility of EO-sterilized products?
Yes. Sterility testing and EO residue testing are often done together for the same batch.
Is this test needed for every batch?
That depends on your validation and quality system. Many manufacturers test during validation and then periodically or per buyer request.